Descriere produs: Multiparameter Monitor CapnoVet Deluxe Features
10.4" color TFT display with 8 waveforms Parameters including ECG, RESP, SpO2, NIBP, TEMP, Pulse Rate, IBP, C.O., EtCO2 Multi-Gas/ O2 Maximum 96-hour graphic and tabular trends of all parameters Recorder and rechargeable battery options Optional wireless LAN card Multi-mode selection for different animals
Technical Specifications Safety Meet the requirements of IEC60601, CE marking to 84/539/EEC, 2004/108/EC Dimension and weightDimension 318 (W) x 270 (D) x 137 (H)mm 12.2" x 8.27" x 5.4" Weight = or < 4.7kg /10.3lb Operation Environment PowerSource AC 100 to 240V, 50/60Hz Temperature 0-40 oC Humidity 15 ~ 95% (non-condensing) Performance SpecificationsDisplay 10.4" color matrix TFT Resolution 800x600 Trace 8waveforms Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s Battery Rechargeable Trend time 1 to 96ours Alarm 10evel audible and visual alarm Recorder (optional) Built-in, thermal array, 2 channels Record paper 50mm Record speed 25mm/s, 50mm/s ECGLead type 5-lead or 3-lead selectable Lead mode 5-lead: RA;LA;RL;LL;V or R;L;N;F;C 3-lead: RA;LA;LL or R;L;F ECG waveform 2 channels Gain selection x0.25; x0.5; x1; x2; auto Sweep speed 12.5mm/s, 25mm/s, 50mm/s Heart rate range 15~350bpm Accuracy 2bpm or 2%, whichever is greater Resolution 1bpm Protection Withstand 4000VAC/50Hz voltage in isolation against electrosurgical interference and defibrillation Calibration signal 1mV 5% Operation modes Diagnostic, Monitor, Surgery Bandwidth Diagnostic mode: 0.5~100Hz Monitor mode: 0.5~40Hz Surgery mode : 1~ 20Hz S-T detection YES Measurement range:-2.0mV~+2.0mV Alarm range: -2.0mV~+2.0mV Arrhythmia analysis YES Pace Detection YES Alarm YES, audible and visual alarm, alarm events recallable Respiration Method Thoracic impedance Measurement range 0-150 rpm Resolution 1 rpm Accuracy 7-150 Brpm: ±2 rpm or ±2%, whichever is greater 0~6 rpm: undefined Apnea Alarm 10 to 40 seconds NIBPMethod Oscillometric Operation modes Manual/Automatic/Continuous Unit mmHg/kPa selectable Parameters Systolic, Diastolic, Mean Range Big cuff mode: Systolic: 40-270mmHG Diastolic: 10-210mmHG Mean: 20-230mmHG Middle cuff mode Systolic: 40-200mmHG Diastolic: 10-150mmHG Mean: 20-165mmHG Small cuff mode Systolic: 40-135mmHG Diastolic: 10-100mmHG Mean: 20-110mmHG Over-pressure protection YES Resolution 1mmHg Accuracy Max Mean error < ±5mmHg Max Standard deviation < 8mmHg PR Range: 40-240bpm Accuracy: ±3bpm or ±3%, whichever is greater TemperatureScale O oC and oF selectable Measurement range 0~50 oC /32~122oF Resolution 0.1 oC /0.1 oF Accuracy +/-0.1oC(excluding the sensor)/ ±0.1oF +/-0.2oC(including the YSI 400 series sensor)/ ±0.2oF Channel 2 Alarm range 0~50oC/32~122oF SpO2 Measurement range 0~100% Resolution 1% Accuracy ±2%( 70~100%) 0~69% :unspecified Alarm range 0~100% Pulse RateRange 20~254bpm Resolution 1bpm Accuracy ±3bpm Nellcor SpO2 Measurement range 0-100% Resolution 1% Accuracy ±2% (70-100%) 0-69%: unspecified Alarm range 0-100% Pulse rate Range: 20-300bpm Resolution: 1bpm Accuracy: ±3bpm (20-250bpm) Unspecified (251 - 300bpm) IBPMeasurement range -50-300mmHG Channel 2 channels Pressure transducer Sensitivity: 5(μV/V/mmHG) Impedance range: 300-3000 (ohm) Transducer sites ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement unit mmHG/kPa selectable Resolutoin 1mmHG Accuracy 1mmHG or ±2%, whichever is greater Pulse rate Range: 25-350bpm Resolution: 1bpm Accuracy: 25-200bpm ±1bpm or 1% whichever is greater 201-350bom ±1% COMethod Thermodilution Measurement range CO:0.1-20L / min. TB: 23-43 oC TI: 0-27 oC Resolution CO:0.1L/min Temperature: 0.1 oC Accuracy:CO: ±1L/min or ±5%, whichever is greater TB: ±0.1 oC TI: ±0.1 oC EtCO2Method Infrared Absorption Mode Sidestream CO2 range 0-99mmHG Resolution 1mmHg Accuracy ±2mmHg (0-40mmHg) ±5% of reading (41-76mmHg) ±10% of reading (77-99mmHg) AWRR range 0-120 rpm Accuracy ±2rpm Multi-Gas/ O2 Method Infrared Absorption Gas sorts CO2, N2O, Des, Iso, Enf, Sev, Hal, O2 (optional, paramagnetic sensor) Range CO2: 0-30% N2O: 0-105% O2: 0-105% Enf, Iso, Hal: 0-30% Sev: 0-30% Des: 0-30% AWRR: 2-100rpm Resolution CO2: 1mmHg AWRR: 1rpm Data output Fi and Et Values Respiration rate ±1rpm (2-60rpm)
|